UPS Online – Offline

On Line/Off Line UPS in Bangladesh

Specifications

Capacity(VA) 10KVA 15KVA 20KVA 40KVA 60KVA 80KVA
Power(W) 9KW 12KW 16KW 36KW 54KW 72KW
 Input
Voltage range (380Vac/ 400Vac/415Vac)±25% (3p, 5w)
Frequency range 50/60Hz±5Hz auto-sensing
Power factor >0.8(without filter),1(with filter)
Rated output current 15A 30A 45A 60A 90A 120A
 Output
Voltage range 380Vac±1% /400Vac/415Vac
Frequency Auto tracking the input frequency
Frequency regulation(battery mode 50Hz/60Hz±0.05%
Waveform Sine wave
Power factor 0.9(lagging)
THD Linear load<3%, Non-linear load<5%
Overload 110%/125%/150% : 60min/10min/1min
Crest factor 3∶1(max)
Efficiency 88% 89% 90% 90% 91% 91%
 Transfer time
AC mode→Battery mode 0ms
Bypass
Rated voltage 380/400/415Vac
Voltage range Upper limit:+10%,+15%,+20% ( can be set)Lower limit:-10%,-20%,-30%,-40% (can be set)
Rated frequency 50/60Hz(auto-sensing)
Frequency range ±2%(±10%, ±20% can be set)
Transfer time 0ms/1ms
Overload 15 times of rated current(10ms),5 times of rated current(5s)
 Battery
Battery voltage(VDC) 384V
Display
LED Input 、inverter、bypass、battery,output status
LCD I/O voltage、frequency、power,power factor,battery voltage、current,battery status,load percentage、UPS status,history record,parameters setting
Communication
Interface Dry contact,RS232,RS485,SNMP card
Environment
Working temperature 0~40℃
Humidity 0~95% non-condensing
Storage temperature -25℃~55℃
Noise(1m) <63dB <67dB
Physical characteristics
Net weight (Kg)380V 225 275 320 335 490 575
Gross weight(Kg)380V 280 330 375 390 560 645
Dimension(W×D×H)mm 555mm*744mm*1220mm 800mm*760mm*1400mm
 Options   
Harmonic filter、SNMP adapter、LBS cables、battery temperature sensor、battery ground fault detection
EMC Safety Standards
EMI IEC62040-2;the output of UPS required by EMC(>16A)
EMS IEC61000-4-2(ESD): Anti-static ability
IEC61000-4-3(RS):Anti-radiation interference ability
IEC61000-4-4(EFT):Anti-interference of power pulse ability
IEC61000-4-5(Surge):Lightning /surging protection ability
Industry Standard YD/T1095-2008

 

Capacity(VA) 100KVA 120KVA 160KVA 200KVA 300KVA 400KVA 500KVA 600KVA 800KVA
Power(W) 90KW 108KW 144KW 180KW 270KW 360KW 450KW 540KW 720KW
Input
Voltage range (380Vac/ 400Vac/415Vac)±25% (3ph, 5w)
Frequency range 50/60Hz±5Hz auto-sensing
Power factor >0.8(without filter),1(with filter) >0.85
Rated output current 152A 182A 243A 304A 456A 608A 760A 912A 1216A
Output
Voltage range 380Vac/400Vac/415Vac±1% or 206Vac±1%
Frequency Auto tracking the input frequency
Frequency regulation(battery mode 50Hz/60Hz±0.05%
Waveform Sine wave
Power factor 0.9(lagging)
THD Linear load<3%, non-linear load<5%
Overload 110%/125%/150% : 60min/10min/1min
Crest factor 3∶1(max)
Efficiency 91% 91.5% 91.5% 92% 93% 94% 94% 94% 94%
Transfer time
AC mode→Battery mode 0ms
Bypass
Rated voltage 380/400/415Vac
Voltage range Upper limit:+10%,+15%,+20% can be setLower limit:-10%,-20%,-30%,-40% can be set
Rated frequency 50/60Hz(auto-sensing)
Frequency range ±2%(±10%, ±20% can be set)
Transfer time 0ms/1ms
Overload 15 times of rated current(10ms),5 times of rated current(5s)
Battery
Battery voltage(VDC) 384V 480V 480V
Display
LED Input 、inverter、bypass、battery,output status
LCD I/O voltage、frequency、power,power factor,battery voltage、current,battery status,load percentage、UPS status,history record,parameters setting
Communication
Interface Dry contact,RS232,RS485,SNMP card
Environment
Working temperature 0~40℃
Humidity 0~95% non-condensing
Storage temperature -25℃~55℃
Noise(1m) <68dB <68dB <70dB <72dB <72dB <72dB <72dB <72dB <72dB
Physical characteristics
Net weight(Kg)380V 1060 1060 1195 1380 1780 2050 3700 4500 6400
Gross weight(Kg)380V 1240 1240 1375 1540 1910 2180 3950 4750 6700
Dimension(W×D×H)mm 1640mm*900mm*1900mm 1640mm*1040mm*1900mm 2800mm*1040mm*1900mm 3900mm*1100mm*1950mm
Options   
Harmonic filter、SNMP adapter、LBS cables、battery temperature sensor、battery ground fault detectionBypass current-sharing inductor
EMC Safety Standards
EMI IEC62040-2;the output of UPS required by EMC(>16A)(>16A)
EMS IEC61000-4-2(ESD): Anti-static ability
IEC61000-4-3(RS):    Anti-radiation interference ability
IEC61000-4-4(EFT):Anti-interference of power pulse ability
IEC61000-4-5(Surge):Lightning /surging protection ability
Industry Standard   YD/T1095-2008

Note:EP600K/EP800K have not yet developed all parameters are just for reference.

On-Line/Off-Line  UPS in Bangladesh

Features and Benefits

* True ON-Line Double convention

* RS 232 communication function

* High input Power Factor

* High performance-price ratio

* Perfect protection function

* Low commercial Power Input Voltage

* Wide Input Voltage Range

* Pure Sine-wave

* Emergency Power Off(EPO) Function

* User-friendly LCD Display

* Digital Control Technology (DCT)

* Variable Fan Speed

* Battery Over Charge & Deep Discharge Protection

Technical Specifications of On Line/Off Line  UPS in Bangladesh

Input

Voltage (VAC)

ST 1000 – 1KVA

ST 2000 – 2KVA

ST 3000 – 3KVA 120-276VAC                    120-276 VAC

ST 6000 – 6KVA

ST 10000 – 10KVA

Frequency: 50 Hz 5%

Number of phase: Single Phase 3 wire

Battery Voltage VDC: Voltage (VAC)
ST 1000 -1KVA : 36

ST 2000 – 2KVA      : 96/72

ST 3000 – 3KVA : 96
ST 6000 – 6KVA : 120/192/240

ST 1000 – 10KVA     : 182/240

Demensions (WxDxH)

ST 1000 -1KVA  145x400x220mm

ST 2000 – 2KVA      192x460x340mm

ST 3000 – 3KVA

ST 6000 – 6KVA     260x570x717mm

ST 1000 – 10KVA

 

Overload Capacity

105-125% load, Lasting 60 Seconds

123-125% load,  Lasting 300 milliseconds

Power factor : 0.7 (Log)

Charging Current

Standard Model : 1A

long Backup :sA

 

Environmental
Voltage (VAC)ST 1000 -1KVAST 2000 – 2KVA        <45 | cBA)ST 3000 – 3KVA
ST 6000 – 6KVAST 1000 – 10KVA      <60 |CBABattery Type Sedeal lead acid maintenance free typical backup time:ST 1000 -1KVA – 15mins (3cells)ST 2000 – 2KVA – 15mins        (6/8 cells)ST 3000 – 3KVA– 15mins (8 cells)ST 6000 – 6KVA– 15mins (16/20 cells)ST 1000 – 10KVA – 15mins (20 cells)

Recharging time: 80-10 hours for 90% capacity

 

Operation

“Line” : When commercial power is normal, light on, abnormal off.

“INV” : Inverter normal, light on, abnormal off.

“Bypass” : UPS in status of bypass supply. light on: in the status of Invention, off

“Fault” : UPS fault. Tight on; normal, off.

“On” : When UPS is shut down, press the button for 0.5 sec. UPS starts up. When UPS is running, press the button for 0.5 sec. UPS will enter battery test model. When battery voltage reaches the low-vltage point or test time lost 10 sec, UPS will stop the function.

“Off” : When UPS is running, press the button for 0.5 sec. UPS will shut down.

“Select” : When UPS normal, LCD display normal output voltage. If the button pressed. the background light on and the LCD display will show input voltage, input frequency, output power. UPS status etc. In addition, when in battery inversion model, press the button for 2 sec, the interval beep can be canceled but warning audio in the status battery low-voltage etc. We offer On Line/Off Line  UPS in Bangladesh.

Protection to Load

Lighting and surge
Short circuit and overload
Over voltage and under voltage
Transients, spike, sag, back out, brownout
Noise (RFI) as per international safety practices

Communications  Interface

Rs232, USB, SNMP (optional) adapter

Instant Power Supply (IPS) 

Technical Specifications

Model Capacity IPS-400 320 Watt IPS-600 480 Watt IPS-800 640 Watt IPS-1000 800 Watt IPS-1500 1200 Watt IPS- 2000 1600 Watt
Input voltage 220V AC=10% Single Phase, 50 Hz
Output voltage 220V AC + 2% for sine wave, 220V AC + 5-10% for square wave (quasi) 50Hz
Protection Over load, Short circuit over charge % deep discharge
Wave form Square wave (quas) or sine wave depends n model
Back Time 2 hours % above, changing time 8-10 hours for 90% of capacity
Battery type SMF/Automotive/industrial, system voltage 12VDc/24VVDc depends on model
Indication AC mains, charging, full charge, inverter, battery low, overload
On Line UPS in Bangladesh, Offline UPS in Bangladesh

IPS Load Distribution on Model

Model Capacity Load  Distribution Power Consumption
IPS-400 320 Watt 2 Tube / 3 CFL + 2 Fan 4’ Tube 60 Watt
IPS-600 480 Watt 3 Tube / 4 CFL + 3 Fan CFL 400 watt up to 26 watt
IPS- 800 640 Watt 4 Tube / 6 CFL + 4 Fan 21 CTV 100 Watt
IPS-1000 800 Watt 5 Tube / 7CFL + 5 Fan PC with LCD 300 watt
IPS- 1500 1200 Watt 8 tube / 12 CFL + 7 Fan 56’’ ceiling fan 100 watt
IPS-2000 1600 watt 10 tube / 15 CFL + 10 Fan PC with CRT 350 Watt
On Line UPS in Bangladesh, Offline UPS in Bangladesh