Why You Should Use Raised Floor While Setup Data Center?

In a data center, a raised floor is a raised floor that is erected two to four feet above the concrete floor. It creates an area where cooling, electrical, and mechanical services may be provided. Raised flooring is often employed as a means of spreading cold air in data centers. Facilities that use a raised floor lower the quantity of air required to cool equipment while also consuming less energy and improving temperature distribution across all cabinets.

The presence of a raised floor might possibly lower the cooling load by as much as 40%, according to studies on the influence of elevated floors on thermal behavior in commercial buildings. When this technology is combined with an AI cooling solution, even more savings may be realized.

Reasons to Choose Floor Raising:

While technological advancements have made it feasible to eliminate the need for elevated flooring, is the decision truly that simple? There are a few things to think about.

Cooling:

Will CRAC units be installed on the perimeter, in-row, above, or as a hybrid? Changing overhead ductwork is more difficult than rearranging floor tiles to optimize airflow patterns and assure cold and hot air separation. Furthermore, overhanging ducting might make cable tray routing and other systems more difficult. Locating chilled water lines above ground is also more difficult in the event of a leak.

Power Management:

How will energy be delivered to the rack? All devices must be able to connect if overhead power is used. Enormous corporate equipment like disk arrays and tape libraries may require power cables to leave the bottom of the rack, and in a non-raised-floor setting, some of these large power wires might be ugly or constitute a trip hazard. When the underfloor area is utilized as a cooling plenum, some equipment may have various airflow requirements (i.e., top or side vented), which is easier to handle.

Maintenance:

Cleaning beneath elevated floor tiles helps to keep contaminants out of the workplace. Dust might enter the equipment through the elevated floor tiles. The good news is that most data centers clean beneath the elevated floors on a regular basis. This keeps the space beneath the elevated floor tiles clean and free of pollutants, lowering the quantity of polluted air forced into the servers, which can lead to equipment failure.

Final Thoughts:

Raised floors are one of the oldest data center architectural standards, but they remain a popular technique for controlling cooling demands and cable rollout. Datacenter administrators can guarantee that their facilities remain efficient and productive for many years to come by harnessing the possibilities of elevated floors. Smart Power and Technologies can assist you with a flawless electrical and data center setup.