Search
Close this search box.

3-3 Phase Series Online UPS (10-160kVA)

Reliable Design

  • The output isolation transformer provides high reliability to adapt different harsh industrial environments and protects the critical loads
  • 100% 3-phase unbalance load adapt to different kinds of complex applications
  • Dual air ducts design offer good cooling to protect the key components and extend the service life
  • Dual power supply redundancy
  • Wide input voltage range provides high adaptability to the grid and extend the battery service life
  • Main PCB board with professional electromagnetic shielding improve reliable performance of EMC

Innovative Upgrade

  • Dual DSP control technology, make the data processing faster and more precise, improve the reliability
  • High output PF=0.9 meet with high requirements of applications
  • ECO-mode (98% Efficiency) gives possibility of significant cost reduction and heat emission
  • Bus synchronization control function provides reliable high power for the dual bus application
  • Advanced no-master-slave parallel technology achieves online power expansion and prevent single fault

Intelligent Management

  • Multiple communication interfaces supports UPS and load intelligent monitoring
  • Intelligent SNMP achieves local monitoring and remote monitor
  • Intelligent fan control according the load capacity reduces the noise and prolongs fan service life
  • Battery self- test function and battery temperature compensation function improve the battery performance and extend battery life
  • Battery temperature compensation function extends battery service life

Humanized Operation

  • 10-30kVA models with wheels enable easy movement
  • HMI – Friendly operation
  • ON/OFF – Double Button design
  • EPO
  • 10,000 history records reduces fault analysis and maintenance time
  • Power components in module design – more compact structure and easy for maintenance
  • Hot-swappable fans design achieves on-line maintenance
Item 3-3 Series Online UPS (10~160kVA)
Power Capacity 10kVA,15kVA,20kVA,30kVA,40kVA,50kVA,60kVA,80kVA,100kVA,120kVA,160kVA
Output Isolated Transformer Standard
Parallel Technology No-master-slave N+1 (Maximum 6pcs)
Input and Output Systems Three-phase input, Three-phase output
Rated Voltage 380/400/415Vac (L-L) settable
Battery Voltage 10~160kVA:348/360Vdc settable
Output Power Factor 0.9
Efficiency 10~30kVA: ≥91%;40~80kVA:≥92%; 100~160kVA:≥93%
Noise < 65 dB
Width × Depth× Height (mm) 10~30kVA : 500×600×1180
40~60kVA : 500×800×1600
80~160kVA :700×800×1800
Communication RS232/RS485, Dry contacts ( MODBUS and SNMP adapter are optional)
×